Brocade SAN

Support Information

Reference Guides

Microcode Guidance

Implementation

Health Check

switchshow
psshow

Load Firmware From USB

usbstorage -e usbstorage -l firmwaredownload -U v9.2.1_EXT

Implementation Checklist

These are the typical items that should be reviewed and/or configured when setting up a new Brocade SAN switch/director. While many of these settings can be set in WebTools, the CLI commands are listed here for a simlper checklist.

User Settings

  • Enable root access optional
userconfig --change root -e yes ; rootaccess --set all
  • Set root password to pre-defined password (Login as root/fibranne and it will prompt you to change)

  • Set admin password to pre-defined password

passwd

Name and Address

  • Set the switch name
switchname new_name
  • Set IP address, subnet mask, gateway
ipaddrset
  • Set the Registered Organization Name (Directors Only)
ron --set <customer_name>

Data Center Settings

  • Verify Management Port Speed (Default is 1000-auto, but some customers need this set to 100-full)
## If 100-full is required
ethif --set eth0 -an off -speed 100 -duplex full

## Validate
ethif --show eth0
  • Configure timezone
tstimezone America/New_York
tstimezone America/Chicago
  • Reboot to make new timezone effective (do this before configurating the clock)

    reboot
    

  • Configure clock

date mmddHHMMyy
  • Configure DNS
dnsconfig --add -domain <domain_name> -serverip1 <ip_address_1> -serverip2 <ip_address_2>
  • Configure NTP server

tsclockserver "ntp_server_name"
- Configure SMTP server

relayConfig --config -rla_ip <relay IP> -rla_dname <domain name>

Licenses

licenseshow

Firmware

  • Update FOS
    firmwaredownload <ftp_server_ip>,<ftp_userid>,<path_to_firmware>
    
  • Configure domain id and set insistent domain ID
switchdisable ; configure

Zone Config

  • Configure default zone policy to No Access
defzone --noaccess ; cfgsave
  • Configure zoning

Optional

  • Persistent disable all ports
    portcfgpersistentdisable 3/0-47
    portcfgpersistentdisable 4/0-47
    portcfgpersistentdisable 5/0-47
    portcfgpersistentdisable 6/0-47
    portcfgpersistentdisable 9/0-47
    portcfgpersistentdisable 10/0-47
    portcfgpersistentdisable 11/0-47
    portcfgpersistentdisable 12/0-47
    

MAPS

  • Enable a policy
    mapspolicy --show -summary
    mapspolicy --enable dflt_conservative_policy
    
  • Verify policy is active
    mapsconfig --show
    mapsconfig --actions raslog,email
    mapsConfig --emailcfg -address rick.k@evolvingsol.com
    mapsconfig --show
    mapsconfig --testmail -subject "this is a test" -message "test email body"
    

Configuring Security

  • Brocade Security Templates This command will show security setup.
    seccryptocfg --show
    
    br6510-fabA-1:FID128:admin> seccryptocfg --show
    SSH Crypto:
    SSH Cipher               : aes128-ctr,aes256-ctr,aes128-gcm@openssh.com,aes256-gcm@openssh.com
    SSH Kex                  : diffie-hellman-group14-sha1,ecdh-sha2-nistp256,ecdh-sha2-nistp384,ecdh-sha2-nistp521
    SSH MAC                  : hmac-sha2-256,hmac-sha2-512
    TLS Ciphers:
    HTTPS                    : !ECDH:!DH:HIGH:-MD5:!CAMELLIA:!SRP:!PSK:!AESGCM:!3DES:!aNULL
    RADIUS                   : !ECDH:!DH:HIGH:-MD5:!CAMELLIA:!SRP:!PSK:!AESGCM:!3DES:!aNULL
    LDAP                     : !ECDH:!DH:HIGH:-MD5:!CAMELLIA:!SRP:!PSK:!AESGCM:!3DES:!aNULL
    SYSLOG                   : !ECDH:!DH:HIGH:-MD5:!CAMELLIA:!SRP:!PSK:!AESGCM:!3DES:!aNULL
    TLS Protocol:
    HTTPS                    : TLSv1.2
    RADIUS                   : TLSv1.2
    LDAP                     : TLSv1.2
    SYSLOG                   : TLSv1.2
    X509v3:
    Validation               : Strict
    

To list security templates that are available:

seccryptocfg --lstemplates
To list the contents of a particular template:
seccryptocfg --show template_file
To apply the configurations in a template file:
seccryptocfg --apply template_file

FCIP Configuration

Resources

FCIP Configuration Steps

Note

The steps shown below are the steps followed in a real world implementation of Brocade 7810s with two 10G links.

Configure GE Interfaces
  1. Show the GE Interfaces and make note of speed and WAN or LAN indication. A flag of L means it is set for LAN (don't want this for FCIP). No L indicates it is set for WAN (this is correct).
    portcfgge --show
    
  2. If needed, set the port for WAN
    portcfgge ge6 --set -wan
    
  3. Set the GE port to 10G
    portcfgge ge2 --set -speed 10G
    portcfgge ge3 --set -speed 10G        
    
  4. Assign IP addresses to the IP interfaces
    portcfg ipif ge2 create 10.1.1.10/24 mtu 1500
    portcfg ipif ge3 create 10.1.1.11/24 mtu 1500
    
  5. If needed, set PMTU for auto MTU size:

    portcfg ipif ge2.dp0 modify 10.1.1.10/24 mtu auto
    portcfg ipif ge3.dp0 modify 10.1.1.11/24 mtu auto
    
  6. Show the IP interfaces

    portshow ipif
    

Configure FCIP Tunnels
  1. Create FCIP tunnel
    portcfg fciptunnel 12 create
    
  2. Enable compression on the tunnel
    portcfg fciptunnel 12 modify -c deflate
    
Configure FCIP Circuits
  1. Create circuits (Do on both sides)
    portcfg fcipcircuit 12 create 0
    portcfg fcipcircuit 12 create 1
    
  2. Add circuit IP addresses (Do on both sides)
    portcfg fcipcircuit 12 modify 0 --local-ip 10.0.0.5 --remote-ip 192.168.0.5
    portcfg fcipcircuit 12 modify 1 --local-ip 10.0.0.6 --remote-ip 192.168.0.6
    
  3. Set min and max bandwidth (Do on both sides)
    portcfg fcipcircuit 12 modify 0 -b 615000 -B 1230000
    portcfg fcipcircuit 12 modify 1 -b 615000 -B 1230000
    
Configure IPsec Encryption
  1. Create an IPsec Policy
    portcfg ipsec-policy MyPolicyName create --preshared-key Li6a28@yfH@sgT28PNUj
    
  2. Verify the IPsec policy is correct on all switches
    portshow ipsec-policy --password
    
  3. Apply the IPSec Policy to the tunnel
    portcfg fciptunnel 12 modify --ipsec MyPolicyName
    
  4. Verify the IPsec configuration was applied to all circuits correctly
    portshow ipsec-policy --ike
    
Validation Commands
  • Show the IP Interfaces
    portshow ipif
    
  • Show the FCIP Tunnel status along with circuits
    portshow fciptunnel -c
    

Brocade SAN Switch Licenses

In order to activate a license, you must have a Transaction Key for each license to be activated along with the License ID (LID) of the appropriate switch.

Obtaining the Transaction Key

A Transaction key is unique key, along with the LID, used to generate a software license from the Broadcom licensing portal. The transaction key is issued when a license is purchased. The transaction key is delivered in one of two methods:

  • Paperpack – The transaction key is printed and delivered within a POD Optic Hardware Kit.
  • E-license – The transaction key is contained in an email that is sent instantly to the customer after the sales order is created. The customer is sent the email message within a few minutes after the sales order is submitted, although the timing will vary depending on the network, internet connection, and so on.

Obtaining the License ID

You must have a license ID to generate the license file in the Broadcom licensing portal. Obtain the license ID of the switch or chassis using the CLI method:

  1. Connect to the switch, and log in using an account with admin permissions.
  2. Enter the following command to display the license ID of the switch:
    license --show -lid
    

Generating a License Key

Use the following procedure to generate and obtain a FOS license key.

  1. Go to https://www.broadcom.com, and then select the LOGIN drop-down at the top-right of the web page.
  2. Click LOGIN or REGISTER. Once logged in, you will be redirected to the Broadcom support portal.
  3. Click Brocade Products. You will be redirected to the Brocade Products page.
  4. Click Licensing. You will be redirected to the Broadcom Licensing Portal page.
  5. Enter the transaction key. Click Next to continue.

    Re-host keys are generated only by the SANnav application and are used only on SANnav. {.is-info}

  6. Enter the license ID (LID) that you obtained earlier in the Unit Information field. Click Next to continue.
  7. Read the Broadcom End User License Agreement, and if you agree to the terms, select the I have read and accept checkbox.
  8. Click Generate to generate the license.
  9. The license key will be sent by email and can also be downloaded by selecting the blue license hyperlink from the Broadcom licensing portal UI.
  10. If a license string is generated, save it to your local folder for future reference.
  11. If an XML certificate file is generated, save it to the remote server, where it will be retrieved for installing the license.

Installing the License Using a License String

For Brocade Gen 6 switches and directors, you must pass the license key in the license --install command to install the licenses.

  1. Connect to the switch, and log in using an account with admin permissions.
  2. Activate the license using the license --install -key command.
    license --install -key HP9ttZNSgmB4MCD3NmNWgQDWtAKBFtXtBSFJF
    
  3. Verify that the license was installed by entering the license --show command. The licensed features that are currently installed on the switch are listed. If the feature is not listed, use the license --install command to install the license.
    license --show
    

Displaying Port License Assignments

When you display the available licenses, you can also view the current port assignment of those licenses. Use the following procedure to display the port license assignments.

  1. Connect to the switch, and log in using an account with admin permissions.
  2. Enter the license --show -port command to view how port licenses are currently assigned.
    license --show -port
    

Static Port Assignment

When Dynamic Ports On Demand (DPOD) is enabled, ports are licensed from a pool of available licenses based on the server blade or switch installation. Each port that is enabled will secure a license on a first-come, first-served basis. If you would like to statically assign port licenses, use the following command. Example below would reserve licenses on the first 16 ports in a switch.

license --reserve -port 0-15

Use the command in the previous section to display the port licenses after making the static assignment to ensure they were properly assigned.

SAN Discovery

Brocade SAN Health

This tool is free of charge to anyone with a Broadcom.com account.

  1. Download and Install the Free Tool Go to this URL and follow the steps to download and install Brocade SAN Health Diagnostic Capture: Download Brocade SAN Health Diagnostics Capture
  2. Before running, turn on automatic upload by clicking the Options button. Click Options
  3. Check the box to Automatically send the BSH file to the report generation queue on audit completion. Automatic Upload
  4. Click Done.
  5. Click the New button to generate a new audit file. This only needs to be done the first time setting up SAN Health. Future runs can be done by opening a saved audit file. Click New
  6. Complete all 5 tabs in the SAN Health Audit. Include Rick Koetter - rick.k@evolvingsol.com or other partners as desired in the Optional Additional Recipients fields. Additional Recipients
  7. Be sure to include all fabrics. There is no good reason to run this multiple times for different fabrics. All fabrics can be included in a single SAN Health report.
  8. Before starting the capture, click on the Save button to save the audit so you can run this report easily with a few clicks in the future.
  9. Start the Audit on the Capture tab after all other tabs are complete and all fabrics have been discovered successfully. The file will upload automatically after all data is completed. Start The Audit
  10. It may take up to several hours for the report to be generated. When it is ready for download, you will receive notification by email. You will be instructed to download the report from https://support.broadcom.com. Your consultant will also receive a copy of the report if you entered their email in the Optional Additional Recipients field.

Generate CSR

seccertmgmt generate -csr https  -type rsa -keysize 2048 -hash sha256 -years 1 -f
seccertmgmt show -csr https -hexdump